Wayne Dalton Torsion idrive Troubleshooting Questions and Answers
1. My iDrive Torsion will not respond to Wall Station or
remotes and there is no audible feedback from operator. What can I check
for?
Verify power at outlet, check the connection at the receptacle,
check connection at operator. If iDrive has power and no audible beeps
are heard Motor Control Board must be replaced.
2. When I press the button to open the door the iDrive chirps 5 times and overhead light flashes.
Operator is in vacation mode. Move the vacation switch located under
the flip cover on the wall station down to lock and back up to unlock.
Operator will beep once indication it is out of vacation mode.
3. One of my hand held remotes does not work but others do.
Replace battery or batteries in the remote and reprogram remote.
4. When I press my Wall Station to open or close door
operators responds with a 1 second, then ½ second beep followed by a
chirp but no operator start.
There is no profile in operator. Run install routine.
5. When I press my Wall Station to open or close door I get one beep.
Motor is not detected check motor connection to operator or replace motor.
6. My door opens 1’ and stops. When I press up/down button again door closes.
Check door balance. Pull red emergency release handle on right hand
side of door and lock into bottom of bracket. Ensure there are no
children or pets in the area of the door. Door should open and close
easily by hand and stay in any position it is raised to. If door is
heavy and falls contact a garage door professional for spring adjustment
or replacement.
7. When I try to open my door motor runs but door does not move.
Re-engage Emergency Disconnect Handle. If handle is engaged and
operator makes a grinding sound internal drive gear is stripped. Replace
operator.
8. My motor will not pivot up or will not stay up.
Detent pin is out of adjustment. Adjust detent pin in/out so right
hand tip just touches face of motor bushing. Disconnect opener and
manually pivot motor up to check.
9. When I run and install routine it does not complete 2 up and down cycles. It goes up, down, up and stops and I get 4 beeps.
Potentiometer nut out of adjustment. Position potentiometer nub 1/8 –
3/16” from left stop of motor control board when door is closed.
10. When I press Wall Station I get no door movement and motor won’t start and operator beeps 6 times.
Damaged Motor Control Board. Replace
11. From open position door will not close and I get 3-4 beeps.
Photo beams not detected. Check alignment of photo beams as well as
wiring at operator. Photo beams must have a solid red LED light on at
all times.